11/22/2016

 
Symptom: Display arrives at desired temperature but measured temperature is more than 30C lower than the set temperature
  • The element may be partially plugged: Make sure to clean off any plastic shavings and debris from your work table, or use the stand to prop up the extruder while not using it.  If the WELDPLAST lays down flat on the table for a length of time, shavings can get sucked in through the air intake and get stuck in the element, blocking the air flow.
WELDPLAST Wiring Instructions
Connecting a plug to your WELDPLAST:
  • Plug specifications for the WELDPLAST S1: 20 Amp or higher; 2 pole; 3 wire; grounding; twist-lock; note mains voltage on tool label
  • Plug specifications for the WELDPLAST S2 & WELDPLAST S4: 20 Amp or higher; 250 Volt; 2 pole; 3 wire; grounding; twist-lock
  • Plug specifications for the WELDPLAST S6: 30 Amp or higher; 250 Volt; 2 pole; 3 wire; grounding; twist-lock
  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab
  • If using a 4 prong plug, leave the pin opposite the one with the bent tab disconnected

Please consider the following when making an extension cord for your WELDPLAST:
  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord

Generator Instructions:
  • Starting procedure:
    1. Switch on the generator
    2. Switch on the WELDPLAST
  • Shut-down procedure:
    1. Switch off the WELDPLAST
    2. Switch off the generator

Comments are closed.
STANMECH Technologies Inc. 
944 Zelco Drive Burlington ON L7L 4Y3 | 1-888-438-6324 | 
info@stanmech.com
Terms of Use    Privacy    Terms and Conditions of Sale   Warranty Policy
Français

Proud Member of:
Picture
Industrial Fabrics Association International
Picture
International Association of Geosynthetic Installers
Picture
​Authorized by the Association of Professional Engineers of Ontario to offer professional engineering services. 
  • Home
  • Equipment
    • All Equipment >
      • Air Heaters
      • Automatic Equipment
      • Blowers
      • Extrusion Welders
      • Hot Air Blowers
      • Hot Air Hand Tools
      • Testing Equipment
    • Flooring
    • Geomembrane
    • Industrial Fabrics
    • Manufacturing
    • Plastic Fabrication
    • Roofing & Decking
  • Services
    • Product Selection Help
    • Engineering Help
    • Installation Support
    • Product Training
    • Product Service
  • Resources
    • Articles
    • Case Studies
    • Engineering Information
    • Operating Manuals
    • Tech Tips
    • Whitepapers
  • About Us
  • Contact
    • Contact Us
    • Find a Distributor
  • Français