FUSION Tech Tips

12/9/2016

 
The FUSION is not producing the correct heat
  • Confirm that the correct element has been installed.  The elements for the FUSION 2 and 3C are not the same as the element for the FUSION 3.
  • Check that the air intake filter (located on the housing in front of the extrusion trigger) is clean. A plugged filter will reduce air flow and heat transfer and could cause the element to burn out. Remove any blockage in the filter with a soft brush.
FUSION Wiring Instructions

Connecting a twist-lock plug to your FUSION:
  • Specifications of the plug: 20 Amp; 250 Volt; 2 pole; 2 wire; non-grounding; twist-lock
  • Connect one wire to either one of the plug pins
  • Connect the other wire to the other pin

Please consider the following when making an extension cord for your FUSION:
  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord

Generator Instructions:
  • Starting procedure:
    1. Switch on the generator
    2. Switch on the FUSION
  • Shut-down procedure:
    1. Switch off the FUSION
    2. Switch off the generator

Comments are closed.
PLEASE NOTE: Both our inbound shipping companies and our outbound couriers are currently advising all customers to expect delays with their parcel deliveries due to drastically increased volumes and the introduction of additional safety measures for their employees. These delays are completely out of our control and we appreciate your patience if they affect delivery of your package
STANMECH Technologies Inc. 
944 Zelco Drive Burlington ON L7L 4Y3 | 1-888-438-6324 | 
info@stanmech.com
Terms of Use    Privacy    Terms and Conditions of Sale
Français

Proud Member of:
Picture
Industrial Fabrics Association International
Picture
International Association of Geosynthetic Installers
Picture
​Authorized by the Association of Professional Engineers of Ontario to offer professional engineering services. 
  • Home
  • Equipment
    • All Equipment >
      • Air Heaters
      • Automatic Equipment
      • Blowers
      • Extrusion Welders
      • Hot Air Blowers
      • Hot Air Hand Tools
      • Testing Equipment
    • Flooring
    • Geomembrane
    • Industrial Fabrics
    • Manufacturing
    • Plastic Fabrication
    • Roofing & Decking
  • Services
    • Product Selection Help
    • Engineering Help
    • Installation Support
    • Product Training
    • Product Service
  • Resources
    • Articles
    • Case Studies
    • Engineering Information
    • Operating Manuals
    • Tech Tips
    • Whitepapers
  • About Us
  • Contact
    • Contact Us
    • Find a Distributor
  • Français